Unsheathed insulated cable
Flame-retardant and fire-resistant wiring for electrical equipment and building wiring at 450/750V and below.
Contact
- For flame-retardant and fire-resistant applications
- Maintains power supply for a certain period during a fire
- Suitable for important facilities with special fire protection requirements.
- Covers both flame-retardant and fire-resistant applications, and can be selected according to project fire protection requirements.
- The fire-resistant type can maintain power supply for a certain period of time in the event of a fire, making it suitable for important facilities.
Detailed Introduction
Unsheathed insulated cables use an insulation layer that directly covers the conductor, with no separate outer sheath on the outside. They are mainly used for internal connections, power distribution, and control circuits of electrical equipment at AC 450/750V and below. Compared with sheathed cables, their structure is simpler, making them suitable for wiring occasions with requirements on installation space and bending radius. The products cover two types of applications: flame-retardant and fire-resistant. The flame-retardant type is used to reduce the risk of flame spreading along the cable, while the fire-resistant type can maintain power supply for a certain period under fire conditions, so it is often used in power stations, high-rise buildings, subways, tunnels, smart buildings, critical factories, complex buildings, and railways. We support customization of conductor material, cross-sectional area, insulation material, color, length, printing, packaging, and product identification. Before purchasing, you can contact us to confirm the specific model and configuration.
- Covers two types of applications: flame-retardant and fire-resistant, which can be selected according to the project's fire protection requirements
- The fire-resistant type can maintain power supply for a certain period under fire conditions, suitable for important facilities
- The rated voltage is AC 450/750V and below, suitable for equipment connections and building wiring
- Supports customization of conductor material, cross-sectional area, insulation material, color, length, printing, packaging, and product identification
- Supplies to construction, power, rail transit, and industrial engineering project parties
- Flame-retardant and fire-resistant applications
| Product Name | Unsheathed insulated cable |
| Product Category | Wires and cables |
| Rated Voltage | AC 450/750 V and below |
| Customization | Supports customization of conductor material, cross-sectional area, insulation material, color, length, printing, packaging, and product identification; |
| MOQ | Contact us to confirm |
| Lead Time | Contact us to confirm |
| Packaging | Contact us to confirm |
| Reference Price | Contact us to confirm |
Applications
- Power distribution and wiring engineering for high-rise buildings, smart buildings, and complex buildings
- Electrical equipment connection and control circuits for subway, tunnel, and railway projects
- Power supply lines for power stations and critical plant buildings, and locations with special fire protection requirements
- Wiring for special facilities such as military warships that require flame retardancy and fire resistance
- Internal equipment connections in industrial projects that require custom conductor material, cross-sectional area, and length according to drawings
Purchasing & Delivery
Before purchasing, it is recommended to confirm the following: whether the required model is flame-retardant or fire-resistant, conductor material and cross-sectional area requirements, insulation material type, color and length, and whether printing, packaging, and product identification customization are needed. Please contact us to confirm price, MOQ, lead time, and certification information. You are welcome to provide dimensions, quantity, and project list, and we will assist in confirming the configuration and provide a quotation.
Service & Support
We support customization of conductor material, cross-sectional area, insulation material, color, length, printing, packaging, and product identification, and can assist in confirming the configuration according to project requirements. If you are selecting models for construction, power, rail transit, or industrial projects, you are welcome to contact us and provide the usage scenario, voltage level, fire protection requirements, and quantity, and we will assist in confirming the suitable model. Please contact us to confirm after-sales support details.
FAQ
What is the difference between unjacketed insulated cable and jacketed cable?
Unjacketed insulated cable has only an insulation layer covering the conductor, with no separate outer jacket; jacketed cable has an additional jacket outside the insulation layer. The unjacketed structure is simpler and is suitable for scenarios such as internal equipment connections, power distribution, and control. The specific selection depends on the installation environment and usage requirements.
What is the rated voltage of this cable?
The rated voltage is AC 450/750V and below, suitable for electrical equipment connection and building wiring. If the project voltage level is different, please contact us to confirm available models.
How to choose between flame-retardant type and fire-resistant type?
The flame-retardant type is mainly used to reduce the risk of flame spreading along the cable; the fire-resistant type can maintain power supply for a certain period of time in the event of a fire, suitable for important facilities with special fire protection requirements, such as power stations, high-rise buildings, subways, and tunnels, etc. For the specific choice, you can contact us to confirm based on the project's fire protection requirements.
Can conductor material, cross-sectional area, and length be customized?
Yes. We support customization of conductor material, cross-sectional area, insulation material, color, length, printing, packaging, and product identification. Please provide the specific dimensions and quantity, and we will assist in confirming the configuration.
How to confirm price, MOQ, delivery time, and certification information?
This information needs to be confirmed based on the specific model and project requirements. You are welcome to contact us and provide the required model, quantity, and usage scenario, and we will assist in confirming the price, MOQ, delivery time, and certification status.
Submit Inquiry
Please fill in the information below, and we will contact you as soon as possible to provide a product solution or quote based on your needs.